(6)
Instructions for the program
1) When data from the computer has any error, the inverter does not accept that data. Hence, in the user program, always
insert a retry program for data error.
2) All data communication, e.g. run command or monitoring, are started when the computer gives a communication request.
The inverter does not return any data without the computer's request. Hence, design the program so that the computer
gives a data read request for monitoring, etc. as required.
3) Program example
To change the operation mode to computer link operation
Programming example of Microsoft
#include <stdio.h>
#include <windows.h>
void main(void){
HANDLE
hCom;
DCB
hDcb;
COMMTIMEOUTS
char
szTx[0x10];
char
szTx[0x10];
char
szCommand[0x10];// Command
int
nTx,nRx;
int
nSum;
BOOL
bRet;
int
nRet;
int
i;
//∗∗∗∗ Opens COM1 port∗∗∗∗
hCom = CreateFile ("COM1", (GENERIC_READ | GENERIC_WRITE), 0, NULL, OPEN_EXISTING, FILE_ATTRIBUTE_NORMAL, NULL);
if (hCom != NULL) {
//∗∗∗∗ Makes a communication setting of COM1 port∗∗∗∗
GetCommState(hCom,&hDcb);
hDcb.DCBlength = sizeof(DCB);
hDcb.BaudRate = 19200;
hDcb.ByteSize = 8;
hDcb.Parity
= 2;
hDcb.StopBits = 2;
bRet = SetCommState(hCom,&hDcb);
if (bRet == TRUE) {
//∗∗∗∗ Makes a time out setting of COM1 port∗∗∗∗
Get CommTimeouts(hCom,&hTim);
hTim.WriteTotalTimeoutConstant = 1000;
hTim.ReadTotalTimeoutConstant = 1000;
SetCommTimeouts(hCom,&hTim);
//∗∗∗∗ Sets the command to switch the operation mode of the station 1 inverter to the network operation mode ∗∗∗∗
sprintf(szCommand,"01FB10000");
nTx = strlen(szCommand);
//∗∗∗∗ Generates sum code∗∗∗∗
nSum = 0;
for (i = 0;i < nTx;i++) {
}
//∗∗∗∗ Generates send data∗∗∗∗
memset(szTx,0,sizeof(szTx));
memset(szRx,0,sizeof(szRx));
sprintf(szTx,"\5%s%02X",szCommand,nSum);// ENQ code+send data+sum code
nTx = 1 + nTx + 2;
nRet = WriteFile(hCom,szTx,nTx,&nTx,NULL);
//∗∗∗∗ Sending ∗∗∗∗
if(nRet != 0) {
//∗∗∗∗ Receiving ∗∗∗∗
}
}
CloseHandle(hCom);
}
}
®
®
Visual C++
//Communication handle
//Structure for communication setting
hTim;
// Structure for time out setting
// Send buffer
// Receive buffer
// For buffer size storing
// For sum code calculation
nSum += szCommand[i];
nSum &= (0xff);
nRet = ReadFile(hCom,szRx,sizeof(szRx),&nRx,NULL);
if(nRet != 0) {
//∗∗∗∗ Displays the receive data ∗∗∗∗
for(i = 0;i < nRx;i++) {
printf("%02X ",(BYTE)szRx[i]);// Consol output of receive data
// Displays ASCII coder in hexadecimal. Displays 30 when "0"
}
printf("\n\r");
}
Communication operation and setting
(Ver.6.0)
// Retrieves current communication information
// Structure size setting
// Communication speed=19200bps
// Data length=8bit
// Even parity
// Stop bit=2bit
// Sets the changed communication data
// Obtains the current time out value
// Write time out 1s
// Read time out 1s
// Changed time out value setting
// Send data (NET operation write)
//Send data size
// Initialization of sum data
// Calculates sum code
// Masks data
// Initialization of send buffer
// Initialization of receive buffer
// Number of ENQ code+number of send data+number of sum code
// Close communication port
4