Prior to disassembling the mixer, plug it into
an electrical outlet and perform a function
test. Test the speed selections, bowl lift
mechanism, and beater to bowl height. For
proper operation and to troubleshoot for the
problem. If the unit's speed ramps up to full
speed and then it shuts off, you need to
check for a tight crimp or replace the Hall
Effect.
After troubleshooting, use the SERVICE
PROCEDURES section to replace any
faulty components.

Service Procedures

This manual is written as a step-by-step guide to
disassemble and reassemble the
Stand Mixer to gain access to the systems within
the unit that are in need of repair. For models
covered in this manual, refer to the index page.
Most of the KitchenAid
components are contained within the motor
housing. Perform the Component Access
Procedure (below) to gain access to the Stand
Mixer components.
Always remove the power cord plug from the
electrical outlet before servicing any part of the
mixer.
NOTE: When removing self-tapping screws
from any plastic or metal housing, the filings
created will be scattered onto adjoining
components. Prior to performing any reassembly
procedure, make sure to remove all the filings
®
KitchenAid
®
Stand Mixer
using clean rags and/or low-pressure compressed
air.
Use of the Troubleshooting Quick Reference
Guide (Appendix B) will aid in determining
what steps are necessary for repairing the unit.
Not all steps will be needed for some of the
repairs so it is important to consult the
Troubleshooting Quick Reference Guide first.
Appendix D lists all of the KitchenAid
Mixer fastener/screw torques required for proper
reassembly of the unit.
Note: Unplug power source, remove the bowl
and any attachments before disassembly of any
unit.
Disassembly Process of New
Generation Stand Mixer
1. Remove Trim Band screw that is located
on the back of the upper housing.(Fig. 1)
Fig. 1 Remove Trim Band
2. Turn the mixer to the side and remove 2
screws in the upper housing.(Fig. 2)
Fig. 2 Remove Upper Housing