OPERATION
Changing breaker flow setting
1. Select breaker flow setting (b) on the Breaker Select Menu
screen, then press switch F6.
2. On the Breaker Oil Flow Setting screen, select one of the two
set values for the oil flow, then press switch F6.
The default values for the oil flow setting are both set to 180
liter/min, as shown in the illustration on the right.
The present oil flow set for B mode is marked with B in front
of the item name as shown in the illustration on the right.
DETAILED CONTROLS AND GAUGES