Properties
Receiver input
*
Depending on the cable used, you can find additional information in the "Industrial Ethernet / PROFINET
)
Passive network components" System Manual, see also section "Introduction", paragraph "Additional
documentation".
8.1.12

SFP992-1LH+

Properties
Transmission mode
Transmission rate
Transmission medium
Light source
Wavelength
Cable length (max.) *
Transmitter output (optical)
Receiver input
*
Depending on the cable used, you can find additional information in the "Industrial Ethernet / PROFINET
)
Passive network components" System Manual, see also section "Introduction", paragraph "Additional
documentation".
8.1.13

SFP992-1ELH

Properties
Transmission mode
Transmission rate
Transmission medium
Light source
Wavelength
Cable length (max.) *
Transmitter output (optical)
Receiver input
*
Depending on the cable used, you can find additional information in the "Industrial Ethernet / PROFINET
)
Passive network components" System Manual, see also section "Introduction", paragraph "Additional
documentation".
Transceiver SFP/SFP+/SCP/STP
Operating Instructions, 10/2023, A5E02630804-18
  Sensitivity min.
Input power max.
  1000Base-ZX complying with IEEE 802.3
  1000 Mbps (Gigabit Ethernet)
  Single mode fiber-optic cable
  Class1-LASER "Eye safe"
  1550 nm
  70 km
)
  Minimum
Maximum
  Sensitivity min.
Input power max.
  1000Base-ZX
  1000 Mbps (Gigabit Ethernet)
  Single mode fiber-optic cable
  Class1-LASER "Eye safe"
  1550 nm
  120 km
)
  Minimum
Maximum
  Sensitivity min.
Input power max.
Technical data
8.1 SFP transceiver
-23 dBm
-3 dBm
0 dBm
5 dBm
-22 dBm
-3 dBm
0 dBm
5 dBm
-32 dBm
-8 dBm