Remote Operation via HP-IB
Trigger
The
group execute tHgger (GET)
or
selective device tHgger
(SDT) command causes all
addressed instruments with HP-IB trigger capability to execute a predefined function
simultaneously The HP 3325B responds to the HP-IB trigger command by starting a single
sweep, providing the HP 3325B is in the enhancements mode and the sweep was reset using
the RSW command.
^
Masking The Status Byte
The HP 3325B MS and ESTB commands specify which bits in the status byte are enabled
(to
generate an SRQ). These commands are described under the HP 3325B Remote Control
Command Set. Table 2-3 describes the HP 3325B status byte and lists the decimal value of
each bit position.
2-9