Dell PowerConnect M6348 Configuration Manual page 52

Configuration guide
Hide thumbs Also See for PowerConnect M6348:
Table of Contents

Advertisement

Figure 3-4. Default Aggregator Groups on Standalone Switch (Blade)
The default Port Aggregator Group mapping is shown in Table 3-2.
Table 3-2. Default Port Aggregator Group Mapping
Aggregator
Member Internal Ports
Group
Group 1
1/xg1,1/xg2,1/xg3,1/xg4, 1/xg5, 1/xg6, 1/xg7,
1/xg8, 1/xg9, 1/xg10, 1/xg11, 1/xg12, 1/xg13,
1/xg14, 1/xg15, 1/xg16
A standalone switch in Simple Mode supports up to 8 Aggregator Groups.
The number of internal ports in an Aggregator Group is unlimited and you can configure any number of
internal ports in each Aggregator Group. The number of external ports that can be included in a group is
limited to the maximum number of ports that can be included in a LAG. On the PowerConnect
M6220/M6348/M8024, eight ports is the maximum number that can be in a LAG. Any member port,
either internal port or external port, is not allowed to participate in more than one Aggregator Group.
52
Switching Configuration
Member Uplink (External) Ports
1/xg17, 1/xg18, 1/xg19, 1/xg20