437
Info.
Started to change the primary volume for the indicated replication set to the indicated volume.
Recommended actions
•
No action required.
438
Info.
Completed changing the primary volume for the indicated replication set to the indicated volume.
Recommended actions
•
No action required.
439
Error
Failed to change the primary volume to the indicated volume for the indicated replication set. This can
occur for several reasons, such as:
•
The volume is not in the replication set.
•
Configuration tag or configuration data not found.
•
The retry limit has been reached.
Recommended actions
•
Verify that the specified volume is part of the replication set.
•
Verify that there are no network issues preventing communication between the storage systems.
440
Warning
Retrying a replication due to an error on the indicated secondary volume. This can occur for several
reasons, such as:
•
The cache request was aborted.
•
The cache detected that the source or target volume is offline.
•
The cache detected a media error.
•
The snap pool is full.
•
The communication link is busy or experienced an error.
•
The snapshot being used for the replication is invalid.
•
There was a problem establishing proxy communication.
The replication is being retried after a moderate delay.
Recommended actions
•
No action required.
441
Error
Failed to forward an add-volume request for a volume in a replication set. The secondary volume cannot
be fully added to the replication set.
Recommended actions
•
Remove the indicated secondary volume from the replication set.
442
Warning
Power-On Self Test (POST) diagnostics detected a hardware error in a UART chip in either or both of the
controllers. The event returns 1 if the Storage Controller (SC) UART failed, 2 if the Management Controller
(MC) UART failed, or 3 if both UARTs failed.
Recommended actions
•
Replace the controller module.