Msa system event descriptions
Hide thumbs Also See for P2000:

Advertisement

437
Info.
Started to change the primary volume for the indicated replication set to the indicated volume.
Recommended actions
No action required.
438
Info.
Completed changing the primary volume for the indicated replication set to the indicated volume.
Recommended actions
No action required.
439
Error
Failed to change the primary volume to the indicated volume for the indicated replication set. This can
occur for several reasons, such as:
The volume is not in the replication set.
Configuration tag or configuration data not found.
The retry limit has been reached.
Recommended actions
Verify that the specified volume is part of the replication set.
Verify that there are no network issues preventing communication between the storage systems.
440
Warning
Retrying a replication due to an error on the indicated secondary volume. This can occur for several
reasons, such as:
The cache request was aborted.
The cache detected that the source or target volume is offline.
The cache detected a media error.
The snap pool is full.
The communication link is busy or experienced an error.
The snapshot being used for the replication is invalid.
There was a problem establishing proxy communication.
The replication is being retried after a moderate delay.
Recommended actions
No action required.
441
Error
Failed to forward an add-volume request for a volume in a replication set. The secondary volume cannot
be fully added to the replication set.
Recommended actions
Remove the indicated secondary volume from the replication set.
442
Warning
Power-On Self Test (POST) diagnostics detected a hardware error in a UART chip in either or both of the
controllers. The event returns 1 if the Storage Controller (SC) UART failed, 2 if the Management Controller
(MC) UART failed, or 3 if both UARTs failed.
Recommended actions
Replace the controller module.