Download Print this page

HP P2000 Reference Manual page 8

Msa system event descriptions
Hide thumbs Also See for P2000:

Advertisement

47
Info.
An error detected by the sensors has been cleared. This event indicates that a problem reported by event
39 or 40 is resolved.
Recommended actions
No action required.
48
Info.
The indicated vdisk has been renamed.
Recommended actions
No action required.
49
Info.
A lengthy SCSI maintenance command has completed. Output indicates whether it completed successfully
or a failure occurred. (Typically appears after disk firmware update.)
Recommended actions
No action required.
50
Info.
A correctable ECC error occurred in buffer memory.
Recommended actions
No action required.
51
Error
An uncorrectable ECC error occurred in buffer memory.
Recommended actions
If this event occurs only once, no action is required.
If the event occurs more than once, replace the controller reporting the event.
52
Info.
Vdisk expansion has started.
Recommended actions
This operation can take days to complete. When complete, event 53 is logged.
53
Info.
Vdisk expansion either completed, failed, or was aborted by a user.
Recommended actions
If the expansion failed because of a disk problem: replace the disk; if vdisk reconstruction starts, wait
for it to complete; and then retry the expansion.
55
Warning
A SMART event occurred on the indicated disk, indicating impending disk failure.
Recommended actions
See
Table 1
56
Info.
A controller has powered up or restarted.
Recommended actions
No action required.
8
on page 42.