47
Info.
An error detected by the sensors has been cleared. This event indicates that a problem reported by event
39 or 40 is resolved.
Recommended actions
•
No action required.
48
Info.
The indicated vdisk has been renamed.
Recommended actions
•
No action required.
49
Info.
A lengthy SCSI maintenance command has completed. Output indicates whether it completed successfully
or a failure occurred. (Typically appears after disk firmware update.)
Recommended actions
No action required.
•
50
Info.
A correctable ECC error occurred in buffer memory.
Recommended actions
•
No action required.
51
Error
An uncorrectable ECC error occurred in buffer memory.
Recommended actions
•
If this event occurs only once, no action is required.
•
If the event occurs more than once, replace the controller reporting the event.
52
Info.
Vdisk expansion has started.
Recommended actions
•
This operation can take days to complete. When complete, event 53 is logged.
53
Info.
Vdisk expansion either completed, failed, or was aborted by a user.
Recommended actions
•
If the expansion failed because of a disk problem: replace the disk; if vdisk reconstruction starts, wait
for it to complete; and then retry the expansion.
55
Warning
A SMART event occurred on the indicated disk, indicating impending disk failure.
Recommended actions
•
See
Table 1
56
Info.
A controller has powered up or restarted.
Recommended actions
•
No action required.
8