Hewlett-Packard NetRAID-4M Controller Installation Guide
Channel 0 terminator (J2)
Channel 3 terminator (J7)
Figure 2-11. Channel Terminator Jumpers

Configuring the Controller

After connecting all devices, reinstall your computer cover, and
connect all power cables. Turn on the external SCSI devices first, and
then turn on the computer. During BIOS initialization, the
HP NetRAID-4M BIOS banner should appear on the screen. If the
BIOS banner does not appear, see Appendix C, Troubleshooting.
Before installing the drivers and software for the HP NetRAID-4M
controller, you may want to configure the controller and the SCSI
devices connected to it (or if your controller and operating system
support it, enable clustering support). To do this, press Ctrl-A when
the following prompt appears:
Press <Ctrl><A> for Configuration Utility
Three options for configuration are available:
Container Configuration Utility (CCU) — CCU allows you to
create, delete, and manage containers from the HP NetRAID-
4M BIOS. You can use CCU to create a bootable container for
the server. We recommend that you configure the server to
boot from a container instead of from a single disk and install
2-16
Channel 1 terminator (J1)
Channel 4 terminator (J8)

Advertisement

Table of Contents
loading

Table of Contents