Hitachi WJ200 Series Instruction Manual page 351

Wj200 series single-phase input 200v class three-phase input 200v class three-phase input 400v class
Hide thumbs Also See for WJ200 Series:
Table of Contents

Advertisement

B−22
Func.
code
C072
Modbus address
Selection of the operation after
C076
communication error
C077
Communication timeout limit
C078
Communication wait time
C096
Communication selection
C098
EzCOM start adr. of master
C099
EzCOM end adr. of master
C100
EzCOM starting trigger
P140
EzCOM the number of data
P141
EzCOM destination 1 adderss
P142
EzCOM destination 1 register
P143
EzCOM source 1 register
P144
EzCOM destination 2 adderss
P145
EzCOM destination 2 register
P146
EzCOM source 2 register
P147
EzCOM destination 3 adderss
P148
EzCOM destination 3 register
P149
EzCOM source 3 register
P150
EzCOM destination 4 adderss
P151
EzCOM destination 4 register
P152
EzCOM source 4 register
P153
EzCOM destination 5 adderss
P154
EzCOM destination 5 register
P155
EzCOM source 5 register
C001~
Input terminal function
C007
Which parameters to be set?
ALL : Set all inverters in the network.
A
: Set admin. inverter (address=1) only.
B
: Set all inverters except admin. inverter.
M
: Set master inverters configured in C098 to C099 of admin. inverter.
Note 5: Address of Administrative inverter is to be set 01 (C072=01).
Note 6: When selection of operation after communication error is set other than "ignoring errors
(C076=02)", EzCOM function is interrupted in case of communication timeout on administrative inverter.
In this case, please power off/on or reset (on/off RES terminal) to recover.
Note 7:.If EzCOM starting trigger is set as input terminal (C100=00), be sure to configure 81 in one of
input terminals.
Note 8: If EzCOM starting trigger is set as always (C100=01), administrative inverter starts to send the
Name
Data/Range
For
1 to 247
ALL
00
ALL
ALL
01
02
ALL
ALL
03
ALL
04
0.00
ALL
0.01~99.99
ALL
0.~1000.
ALL
00
-
01
B
02
A
01 to 08
A
01 to 08
A
00
A
01
A
1 to 5
M
1 to 247
M
0000 to FFFF
M
0000 to FFFF
M
1 to 247
M
0000 to FFFF
M
0000 to FFFF
M
1 to 247
M
0000 to FFFF
M
0000 to FFFF
M
1 to 247
M
0000 to FFFF
M
0000 to FFFF
M
1 to 247
M
0000 to FFFF
M
0000 to FFFF
M
81
A
Description
Network address
tripping
tripping after decelerating
and stopping the motor
ignoring errors
stopping the motor after
free-running
decelerating and stopping
the motor
Disabled
[sec.]
[ms]
Modbus-RTU
EzCOM
EzCOM
< Admin. inverter >
Input terminal (Note 2)
Always
(Note 3)
485: start EzCOM