Parameter Settings For Keypad Entry; Main Profile Parameters - Hitachi WJ200 Series Instruction Manual

Wj200 series single-phase input 200v class three-phase input 200v class three-phase input 400v class
Hide thumbs Also See for WJ200 Series:
Table of Contents

Advertisement

C−2
Introduction
This appendix lists the user-programmable parameters for the
and the default values for European and U.S. product types. The right-most column of
the tables is blank, so you can record values you have changed from the default. This
involves just a few parameters for most applications. This appendix presents the
parameters in a format oriented toward the keypad on the inverter.

Parameter Settings for Keypad Entry

WJ200
series inverters provide many functions and parameters that can be configured
by the user. We recommend that you record all parameters that have been edited, in
order to help in troubleshooting or recovery from a loss of parameter data.
Inverter model
MFG. No.

Main Profile Parameters

NOTE:. Mark " " in B031=10 shows the accessible parameters when B031 is set "10",
high level access.
Func.
Code
Output frequency setting
F001
Acceleration time (1)
F002
Acceleration time (1),
F202
2
motor
nd
Deceleration time (1)
F003
Deceleration time (1),
F203
2
motor
nd
Keypad RUN key routing
F004
WJ200
"F" Function
Name
Standard default target
frequency that determines
constant motor speed, range is
0.0 / start frequency to
maximum frequency (A004)
Standard default acceleration,
range is 0.01 to 3600 sec.
Standard default deceleration,
range is 0.01 to 3600 sec.
Two options; select codes:
00 ...Forward
01 ...Reverse
This information is printed
on the specification label
located on the right side
of the inverter
Description
WJ200
series inverters
Defaults
Run
Mode
Lnitial data
Units
Edit
0.0
Hz
10.0
sec.
10.0
sec.
10.0
sec.
10.0
sec.
00