6. Lift the small handle
Figure 35. Accessing the microprocessor
7. Lift the microprocessor straight up and out of the microprocessor socket.
Notes:
• Your microprocessor and socket might look different from the one illustrated.
• Touch only the edges of the microprocessor. Do not touch the gold contacts on the bottom.
• Do not drop anything onto the microprocessor socket while it is exposed. The socket pins must be
kept as clean as possible.
Figure 36. Removing the microprocessor
8. Ensure that the small handle is in the raised position and the microprocessor retainer is fully open.
9. Remove the protective cover that protects the gold contacts of the new microprocessor.
1
and open the retainer
.
Chapter 9
2
to access the microprocessor
Replacing FRUs (machine types: 10B0, 10B1, 10B2, and 10B3)