12
-
13
-
14
-
15
-
16
-
Command action
1 List RAID Arrays
2 List Internal Disks
3 Make Mirroring Arrays
4 Repair Mirroring Arrays
5 Delete Mirroring Arrays
6 Remove Disk Partitions
7 Make Striping Array
8 Delete Striping Array
c Configurations
q Quit
Command: 4 (If the system does not synchronized the replaced disk
automatically, execute the below command to restore to the RAID
configuration manually.)
[Repair Mirroring Arrays(RAID1)]
* Which SCSI SLOT? [1-16] 9
Command action
1 List RAID Arrays
2 List Internal Disks
3 Make Mirroring Arrays
4 Repair Mirroring Arrays
5 Delete Mirroring Arrays
6 Remove Disk Partitions
7 Make Striping Array
8 Delete Striping Array
c Configurations
q Quit
Command: 1 (Check if the resynchronization process is started.)
[List of RAID Arrays]
Name
Partition
============================================================
< Mirroring Array (RAID1)>
md0
/boot
md1
swap
md2
/
md3
/var/crash
(Perform restoration (RECOVERY) to each RAID devices (md). After
a while, check the Status with the below command. "RESYNC" shows
it is waiting to be restored. "R" is displayed on the left side
of the Member. This indicates the disk partition is either waiting
to be restored or is in the process of restoring.)
(RAID1)
(RAID1)
(RAID1)
(RAID1)
(RAID1+0)
(RAID1+0)
(RAID1)
(RAID1)
(RAID1)
(RAID1)
(RAID1+0)
(RAID1+0)
(Label)
Status
( - )
RECOVERY (62%)
( - )
RESYNC
( - )
RESYNC
( - )
RESYNC
Linux Setup and Operation 3-7
Member
(1)sda1
R(9)sdi1
(1)sda2
R(9)sdi2
(1)sda3
R(9)sdi3
(1)sda5
R(9)sdi5