Windows Related - Fujitsu PRIMEQUEST 2000 Series Message Reference

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Messages
Meaning:
Device failed to start after reset
Corrective action:
Replace IB HCA card.
Severity:
Error
18029
Failed to reset HCA
Meaning:
An error occurred during reset of HCA
Corrective action:
Replace IB HCA card.
Severity:
Error
18030
Failed to initialize
Meaning:
An error occurred during initialization.
Corrective action:
Replace IB HCA card.
Severity:
Error
18048
NOP command failed to generate interrupt
Meaning:
An error occurred during interruption.
Corrective action:
Replace IB HCA card.
Severity:
Warning

2.2.2 Windows related

■ LAN (windows) related
21709
Adapter error (Could not establish link)
Meaning:
A link cannot be established.
Corrective action:
Check the cable.
Severity:
Warning
21710
Adapter error (NOT properly configured)
Meaning:
The PRO/1000 adapter is not properly configured in the PCI BIOS.
Corrective action:
If the unit name is IOB#n-PCIC#n-FUNC#n or PCI_Box#n-PCIC#n-FUNC#n:
>> Try again with another PCI slot. Alternatively, replace the adapter.
- If the unit name is SB#n-NIC:
>> Replace the SB.
Severity:
Error
105