MMB Messages
Warning
C8A90405
PCI Express Speed degraded
Meaning:
Speed degradation was detected in the PCIe Switch PCIe Port.
Corrective action:
The target SB, IOU, or PCI_Box must be replaced. Contact your sales representative or a field engineer.
Severity:
Warning
C8A90504
PCI Express Lane degraded
Meaning:
Lane degradation was detected in the Onboard GbE/SAS, PCI card or SAS/RAID card.
Corrective action:
The target SB/IOU/DU/PCI_Box or the PCI card must be replaced. Contact your sales representative or a
field engineer.
Severity:
Warning
C8A90505
PCI Express Speed degraded
Meaning:
Speed degradation was detected in the Onboard GbE/SAS, PCI card or SAS/RAID card.
Corrective action:
The target SB/IOU/DU/PCI_Box or the PCI card on IOU/PCI_Box must be replaced. Contact your sales
representative or a field engineer.
Severity:
Warning

2.1.17 Module related

The messages related to the module are listed below.
C9A10290
BMC Communication Error
Meaning:
There was error in a normal BMC.
Corrective action:
The system board must be replaced. If the error persists, the Active MMB must be replaced.
Severity:
Warning
C9A30290
BMC Communication Failure
Meaning:
The error could not be resolved by BMC reset.
Corrective action:
The system board must be replaced. If the error persists, the Active MMB must be replaced.
Severity:
Error