Fan Related - Fujitsu PRIMEQUEST 2000 Series Message Reference

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Messages
Meaning:
High voltage warning was canceled.
Corrective action:
No action is necessary.
Severity:
Info
028109FF
Upper Critical - going high Deassert $$$V threshold: $$$V
Meaning:
High voltage error was canceled.
Corrective action:
No action is necessary.
Severity:
Info

2.1.3 Fan Related

Fan related messages are listed below.
040102FF
Lower Critical - going low Assert $$$rpm threshold: $$$rpm
Meaning:
Low FAN rpm error has occurred.
Corrective action:
Replace the target IO_FAN or FANM. When the situation does not improve even if FANM is exchanged,
replace the target PSU or FANU.
However, when the same event occurs by two or more FAN mounted to same PSU or same FANU, replace
the target PSU or FANU.
Severity:
Error
040107FF
Upper Non-critical - going high Assert $$$rpm threshold: $$$rpm
Meaning:
High FAN rpm warning has occurred.
Corrective action:
Replace the target IO_FAN or FANM. When the situation does not improve even if FANM is exchanged,
replace the target PSU or FANU.
However, when the same event occurs by two or more FAN mounted to same PSU or same FANU, replace
the target PSU or FANU.
Severity:
Warning
040800FF
Device absent
Meaning:
FAN is not mounted.
Corrective action:
No action is necessary.
Severity:
Info
040801FF
Device present
Meaning:
FAN is mounted.
Corrective action:
No action is necessary.
C122-E178-02EN