Cpu Related - Fujitsu PRIMEQUEST 2000 Series Message Reference

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Messages

2.1.15 CPU related

CPU related messages are listed below.
C8A00600
Correctable QPI Path error { (SB#x-CPU#Y) }
Meaning:
A correctable error was detected in the QPI transmission path between the CPUs.
Maximum two CPUs that detected the error are specified in {}.
Corrective action:
No action is necessary.
Severity:
Info
C8A10600
Uncorrectable Internal error
Meaning:
An Uncorrectable CPU error has occurred.
Corrective action:
CPU must be replaced. Contact your sales representative or a field engineer.
Severity:
Error
C8A10601
Uncorrectable QPI Path error { (SB#x-CPU#Y) }
Meaning:
An uncorrectable error was detected in the QPI transmission path between the CPUs.
Maximum two CPUs that detected the error are specified in {}.
Corrective action:
CPU must be replaced. Contact your sales representative or a field engineer.
Severity:
Error
C8A20600
Fatal Internal error
Meaning:
A fatal error was detected in the CPU.
Corrective action:
CPU must be replaced. Contact your sales representative or a field engineer.
Severity
Error
C8A20601
Fatal QPI Path error { (SB#x-CPU#Y) }
Meaning:
A Fatal error was detected in the QPI transmission path between the CPUs.
Maximum two CPUs that detected the error are specified in {}.
Corrective action:
CPU must be replaced. Contact your sales representative or a field engineer.
Severity:
Error
C8A706FF
Correctable error logging limit reached
Meaning:
Correctable errors occurred frequently in the CPU, and the replacement threshold has been reached.
Corrective action:
CPU must be replaced. Contact your sales representative or a field engineer.