Fan Related - Fujitsu PRIMEQUEST 2000 Series Message Reference

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Messages

2.1.3 Fan Related

Fan related messages are listed below.
040102FF
Lower Critical - going low Assert $$$rpm threshold: $$$rpm
Meaning:
Low FAN rpm error has occurred.
Corrective action:
Replace the target IO_FAN or FANM. When the situation does not improve even if FANM is exchanged,
replace the target PSU or FANU.
However, when the same event occurs by two or more FAN mounted to same PSU or same FANU, replace
the target PSU or FANU.
Severity:
Error
040107FF
Upper Non-critical - going high Assert $$$rpm threshold: $$$rpm
Meaning:
High FAN rpm warning has occurred.
Corrective action:
Replace the target IO_FAN or FANM. When the situation does not improve even if FANM is exchanged,
replace the target PSU or FANU.
However, when the same event occurs by two or more FAN mounted to same PSU or same FANU, replace
the target PSU or FANU.
Severity:
Warning
040800FF
Device absent
Meaning:
FAN is not mounted.
Corrective action:
No action is necessary.
Severity:
Info
040801FF
Device present
Meaning:
FAN is mounted.
Corrective action:
No action is necessary.
Severity:
Info
040B00FF
Fully Redundant
Meaning:
FAN is redundant.
Corrective action:
No action is necessary.
Severity:
Info
040B03FF
Non-redundant: Sufficient Resource
Meaning:
FAN is non-redundant.
Corrective action:
No action is necessary. However, if other messages are displayed, check the corresponding corrective
action.
Severity:
Warning
7
CA92344-0540-06