MMB Messages
090B05FF
Non-redundant: Insufficient Resource
Meaning:
The mounted PSUs are not sufficient for system operation.
Corrective action:
Check for any faulty PSU, and if the mounted PSUs are sufficient for system configuration.
Severity:
Error

2.1.5 MMB related

MMB related messages are lased below.
15070103
Chassis Information access failure
Meaning:
The cabinet information was corrupted.
Corrective action:
An MMB must be replaced. Contact your sales representative or a field engineer.
Severity:
Warning
15070107
MMB Communication Lost (LAN)
Meaning:
LAN communication between MMBs was disconnected.
Corrective action:
An MMB must be replaced. If normal operation could not be restored, the other MMB must be replaced.
Severity:
Warning
Remarks
This is basically an error on the Standby side.
15070108
MMB Communication Lost (COM)
Meaning:
COM port communication between MMBs was disconnected.
Corrective action:
An MMB must be replaced. If the operation could not be restored, the other MMB must be replaced.
Severity:
Warning
15070119
MMB Watchdog Timer expired
Meaning:
The Watchdog Timer has timed out.
Corrective action:
An MMB must be replaced. Contact your sales representative or a field engineer.
Severity:
Warning
1507011A
Heartbeat Lost
Meaning:
Another system MMB has failed.
Corrective action:
An MMB must be replaced. Contact your sales representative or a field engineer.
Severity:
Warning