List Of Svas Message Ids - Fujitsu PRIMEQUEST 2000 Series Message Reference

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Messages
E76F0906
SSD Rated Write Endurance has reached 80% (PCI_Box or IOU#n-Slot#n-Port#n, Cascade#, %s)
%s: Disk enclosure model name (e.g. "JX40")
Meaning:
SSD Rated Write Endurance has reached 80%.
Corrective action:
Please prepare the replacement part of SSD.
Severity:
Info
E76F0907
SSD Rated Write Endurance has reached 80%
Meaning:
SSD Rated Write Endurance has reached 80%.
Corrective action:
Please prepare the replacement part of SSD.
Severity:
Info
E76F0908
SSD Rated Write Endurance has reached 90% (PCI_Box or IOU#n-Slot#n-Port#n, Cascade#, %s)
%s: Disk enclosure model name (e.g. "JX40")
Meaning:
SSD Rated Write Endurance has reached 90%.
Corrective action:
Replace the SSD.
Severity:
Info
E76F0909
SSD Rated Write Endurance has reached 90%
Meaning:
SSD Rated Write Endurance has reached 90%.
Corrective action:
Replace the SSD.
Severity:
Info
2.2

List of SVAS message IDs

This section lists the messages related to the SVAS.
SVAS outputs the log to SEL of MMB in the following either event ID detecting the message of the device
driver.
- BC507000
- BC508000
- BC509000
- BC547000
- BC548000
- BC549000
Message ID is included in the output log, and the action is executed according to the following message ID
list. Please confirm details of the message that the device driver output by the event log of OS.
77
CA92344-0540-06

Advertisement

Table of Contents
loading

Table of Contents