Voltage Sensor Related - Fujitsu PRIMEQUEST 2000 Series Message Reference

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Messages
018107FF
Upper Non-critical - going high Deassert $$$℃ threshold: $$$ ℃
Meaning:
High-temperature warning was canceled.
Corrective action:
No action is necessary.
Severity:
Info
018109FF
Upper Critical - going high Deassert$$$°C threshold: $$$°C
Meaning:
High-temperature error was canceled.
Corrective action:
No action is necessary.
Severity:
Info
01810BFF
Upper Non-recoverable - going high Deassert $$$°C threshold: $$$°C
Meaning:
High temperature error (Ultra-high level processing) was canceled.
Corrective action:
No action is necessary.
Severity:
Info

2.1.2 Voltage Sensor Related

Voltage Sensor related messages are listed below.
020100FF
Lower Non-critical - going low Assert $$$V threshold: $$$V
Meaning:
Low voltage warning has occurred.
Corrective action:
Target board must be replaced.
Severity:
Warning
020102FF
Lower Critical - going low Assert $$$V threshold: $$$V
Meaning:
Low voltage error has occurred.
Corrective action:
Target board must be replaced.
Severity:
Error
020104FF
Lower Non-recoverable - going low Assert $$$V threshold: $$$V
Meaning:
Low voltage error has occurred.
Corrective action:
Target board must be replaced. When "Unit" in SEL is SB#xx identify the replacement parts by referring to
'TABLE A.2 Replacement component list
Severity:
Error
2'.
5
CA92344-0540-06

Advertisement

Table of Contents
loading

Table of Contents