Advertisement

Dynamic Reconfiguration Messages
dr-util:ERR:%d: IOU<x> status is invalid: <y>
[%d: 453, 454]
Meaning:
The status of IOU slot <X> is invalid.
Corrective action:
Failed to check the IOU<x> slot status.
Please gather the information for investigation by using "/opt/FJSVdr-util/sbin/dr report" on the partition side,
and contact the technology of our company member
dr-util:ERR:%d: Internal Error
[%d: 455, 456]
Meaning:
Internal error occurred.
Corrective action:
Please gather the information for investigation by using "/opt/FJSVdr-util/sbin/dr report" on the partition side,
and contact the technology of our company member.
dr-util:ERR:460: Failed to add Pcie<x> with error <y>.
Meaning:
Failed to add PCIe<x> with error number <y>
Corrective action:
The addition of PCIe<x> failed because of the error <y>
Please confirm the error messages and do corrective action according to error.
dr-util:ERR:461: Failed to remove Pcie<x> with error <y>.
Meaning:
Failed to remove PCIe<x> with error number <y>
Corrective action:
The remove of PCIe<x> failed because of the error <y>
Please confirm the error messages and do corrective action according to error.
Please try removing of PCIe again. When the improvement is not seen even if it executes it again, please
gather the information for investigation by using "/opt/FJSVdr-util/sbin/dr report" on the partition side, and
contact the technology of our company member
dr-util:ERR:%d: PCIe<x> status is invalid: <y>.
[%d: 462, 463]
Meaning:
The status of PCIe slot <X> is invalid
Corrective action:
Failed to check the PCIe<x> slot status
Please gather the information for investigation by using "/opt/FJSVdr-util/sbin/dr report" on the partition side,
and contact the technology of our company member
dr-util:ERR:%d: Internal Error.
[%d: 470-483]
Meaning:
Internal error occurred.
Corrective action:
Please gather the information for investigation by using "/opt/FJSVdr-util/sbin/dr report" on the partition side,
and contact the technology of our company member.
3.4
Messages concerning trouble that occurs outside of DR
command other than OS kernel
dr-util:ERR:%d: Failed to send IPMI Command: Completion
[%d: 600, 602]
Meaning:
Failed to send IPMI Command
Corrective action:
Failed to send the completion notification of SB hot plug to MMB. Please check MMB status.