Sharp UP-600 Service Manual page 23

Sharp up-600 cash register service manual
Hide thumbs Also See for UP-600:
Table of Contents

Advertisement

4)-3. CH2 Check
Checking
The procedure for checking, display and the method of exiting the
programs are the same as for the CH1 check.
4)-4. CH3 Check
Checking
The procedure for checking, display and the method of exiting the
program are the same as for the CH1 check.
4)-5. CH4 Check
Checking
The procedure for checking, display and the method of exiting the
program are the same as for the CH1 check.
4)-6. CH5 Check
Checking
The procedure for checking, display and the mothod of exiting the
programs are the same as for the CH1 check.
4)-7. CH6 Check
Checking
The procedure for checking, display and the method of exiting the
programs are the same as for the CH1 check.
4)-8. CH7 Check
Checking
The procedure for checking, display and the method of exiting the
programs are the same as for the CH1 check.
4)-9. CH8 Check
For checking CH8, the following loop-back connector is used.
RS
1pin
ER
2pin
SD
3pin
CI/CD
4pin
GND
5pin
RD
6pin
DR
7pin
CS
8pin
Checking
The following checks are performed.
i. Control signal check
ER8
RS8
DR8
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
The program performs the read checks of the above inputs.
During the read check, ER and RS are changed over in the above
order, checking the logic of DR, CI, CD and CS.
If the logic is different from those listed in the table, the error
message appears.
Ci8
CD8
CS8
OFF
OFF
OFF
ON
OFF
ON
PATTERN 1
ER8
RS8
OFF
ON
ON
OFF
ON
ON
"No Connect" is displayed on the next line of PASS!!.
PATTERN 2
ER8
RS8
OFF
ON
ON
OFF
ON
ON
"CI Connect is displayed on the next line of PASS!!
PATTERN 3
ER8
RS8
OFF
ON
ON
OFF
ON
ON
"CD Connect! is displayed on the next line of PASS!!
If the logic is different from those in PATTERN 1 - 3, the error
message appears.
"ON" means active low and "OFF" active high.
The above checks are repeated for four cycles.
ii. Data transfer check
As check data, loop back data transfer of 256 bytes of 00H - 0FFH
is performed, the baud rate is set for115200 bps.
Display
RS232 CH8 Check
PASS!!(or ERROR!!)
CD Connect(or CI
Details of the errors are printed on the journal.
ERROR
ERROR print
No.
1
ER-DR : ERROR
2
ER-CI : ERROR
3
RS-CD : ERROR
4
RS-CS : ERROR
5
6
7
8
TXEMP : ERROR
9
TXEMP INT : ERROR
10
TXRDY : ERROR
11
TXRDY INT : ERROR
CI8
CD8
OFF
OFF
OFF
OFF
OFF
OFF
CI8
CD8
OFF
OFF
ON
OFF
ON
OFF
CI8
CD8
OFF
OFF
OFF
ON
OFF
ON
Connect, No Connect
)
Details of ERROR
ER-DR LOOP ERROR
ER-CI LOOP ERROR
RS-CD LOOP ERROR
RS-CS LOOP ERROR
TXEMP is not set.
TXEMP interrupt does not
occur.
TXRDY is not set.
TXRDY interrupt does not
occur.