19 Remove the drive roller from the plotter.
Reassembling: Ensure that the bearing
assembly at the right end of the drive
roller is seated in the right sideplate and
completely on the right side of the axial
bias plate.
Bearing assembly
Axial bias plate
Calibration: Perform the accuracy
calibration after installing the drive
roller. (Details D chapter 7.)