Procedure 12: Configuring The E1 Ports Using The Cli - Motorola Canopy T1 User Manual

Hide thumbs Also See for Canopy T1:
Table of Contents

Advertisement

Canopy  T1/E1 Multiplexer 
 
 
 
Action
Set backup clock
reference line
Log off
Follow this procedure to configure the E1 ports from the CLI manager.
Action
Log in
Press Enter.
At the username prompt, enter admin.
At the password prompt, enter password.
Set E1 line length
NOTE: If the incorrect line length is selected, the result could be decreased
E1 quality or echo on voice lines. The default length is 133 ft.
Enter
where
[1/2/3/4] represents E1 ports 1 through 4.
[133, 266, 399, 533, 655] represents line length in feet.
RESULT: The system responds
Line [1/2/3/4] length
dB; 266-399 / 1.8 dB; 399-533 / 2.4 dB; 533-655 / 3.0
dB]
 
Issue 1
 
 
 
 
 
NOTE: This is the optional backup clock reference for all four T1/E1 lines.
The backup clock reference becomes active only when the master clock
reference line is unavailable. The default setting is T1/E1 Port 2.
Enter set secondary clock reference line [1/2/3/4]
where
[1/2/3/4] represents T1/E1 ports 1 through 4.
RESULT: The system responds
Backup clk ref line; [1/2/3/4]
Enter lo.
RESULT: The system responds goodbye.
end of procedure

Procedure 12: Configuring the E1 ports using the CLI

set line [1/2/3/4] length [133, 266, 399, 533]
 
 
 
     
 
    T1/E1 Multiplexer Release 3.1 
Steps
Steps
[0-133 / 0.6 dB; 133-266 / 1.2
 
 
          June 2004 
 39 of 69 
Page