Canopy T1/E1 Multiplexer
Action
Set backup clock
NOTE: This is the backup clock reference for all four T1/E1 lines. The
reference line
backup clock reference becomes active only when the master clock
reference line is unavailable. The default setting is T1/E1 Port 2.
Enter set secondary clock reference line [1/2/3/4]
where
[1/2/3/4] represents T1/E1 ports 1 through 4.
RESULT: The system responds
Backup clk ref line; [1/2/3/4]
Log off
Enter lo.
RESULT: The system responds goodbye.
2.4.6
Configure Timing
Before the timing may be configured, you need to determine the network timing scheme
to be used. You also need to identify the master and slave devices for the end-user PBX
equipment.
Action
Log in
Set master clock
reference line
Issue 1
end of procedure
Procedure 13: Configuring timing using the CLI
Press Enter.
At the username prompt, enter admin.
At the password prompt, enter password.
NOTE: This is the master clock reference for all four T1/E1 lines.
The default setting is T1/E1 Port 1.
Enter set master clock reference line [1/2/3/4]
where
[1/2/3/4] represents T1/E1 ports 1 through 4.
RESULT: The system responds
Clk ref line; [1,2,3,4]
T1/E1 Multiplexer Release 3.1
Steps
Steps
June 2004
41 of 69
Page