General Description 2-25
CPU/IO Module Status
The CPU/IO module (0 or 1) started first is managed as primary, and the module started later is
managed as secondary. If one CPU/IO module is disconnected because of the failure and others,
theother module becomes primary.
The CPU/IO module to be started first is selected depending on the primary/secondary status of
modules when the server was shut down the last time. When the server is started for the first time
after power OFF, the CPU/IO module which was powered ON first becomes primary.
Notes on optical disk drive
After ft control software is installed, an optical disk drive becomes inaccessible. When accessing
to an optical disk drive is necessary, follow the procedure below to temporarily allow access to
the drive.
# /opt/ft/sbin/enable-usb-storage
Use of optical disk drive in normal operation is not recommended. Do not operate the server
while using the optical disk drive, such as mounting on service console or allocating to guest OS.
When an optical disk drive is used during the system operation, the product may not work
properly. If an optical disk drive is used, remove the mounted / allocating optical disk drive and
reboot the system.