Replacing A Hard Disk Drive - NEC N8800-149F User Manual

Table of Contents

Advertisement

Replacing a hard disk drive

To replace a failing hard disk, follow the steps below. Replace a hard disk when the CPU/IO module
0 and 1 are powered on.
Determining a failing disk
This section provides information on how to determine a failing hard disk drive.
IMPORTANT:
This must be operated by root user.
1.
Execute "mpmadm -l"commands.
2.
Check the failed disk form the displayed info.
The following is an example when a failure occurred on the internal disk stored in the slot 0 of PCI
module 1.
# cd /opt/ft/sbin/
# ./mpmadm -l
mpm0 [2/2]
|_ vmhba110500:C0:T0:L0
|_ vmhba100500:C0:T0:L0
When you confirm the slot0 of PCI Module1 by "/opt/ft/bin/ftsmaint ls" command,
follows.
# cd /opt/ft/bin/
# ./ftsmaint ls 11/40/1
H/W Path
Description
State
Op State
Reason
・・・・
・・・・
[ faulty ]
[ in_sync ]
: 11/40/1
: Disk Drive
: BROKEN
: SHOT
: NONE
・・・・
・・・・
ESX Operation and Configuration 3-5
i
t is displayed as

Advertisement

Table of Contents

Troubleshooting

loading