Chapter 2. Adjustments; Adjustments - Sharp UX-510A Service Manual

Hide thumbs Also See for UX-510A:
Table of Contents

Advertisement

CHAPTER 2. ADJUSTMENTS

[1] Adjustments

General
Since the following adjustments and settings are provided for this model,
make adjustments and/or setup as necessary.
1. Adjustments
Adjustments of output voltage (FACTORY ONLY)
1. Install the power supply unit in the machine.
2. Set the recording paper and document.
3. When the document is loaded, power is supplied to the output lines.
Confirm that outputs are within the limits below.
Output voltage settings
CNTH
TEL/LIU
CONTROL
PWB
PWB
CNLIUA
CNLIUA
CNLED
CNSP
CNCSW
CNCCD
Output
Voltage limits
4.75V ∼ 5.25V
+5V
23.3V ∼ 24.7V
+24V
2. IC protectors replacement
ICPs (IC Protectors) are installed to protect the motor driver circuit.
ICPs protect various ICs and electronic circuits from an overcurrent con-
dition.
The location of ICPs are shown below:
CONTROL
PWB (TOP SIDE)
CNLIUA
(1) FU100 (KAB2402) is installed in order to protect IC's from an over-
current generated in the motor drive circuit. If FU100 is open, replace
it with a new one.
POWER
SUPPLY
PWB
CNPW
CNMT
CNPN
Connector
No.
CNPW
Pin No.
1
+24V
2
+24V
3
MG
4
MG
5
+5V
6
DG
7
PSAVE
8
DG
FU100
3. Settings
(1) Dial mode selector
DIAL mode (Soft Switch No. SWB4 DATA No. 3)
(step 1) Select "OPTION SETTING".
KEY :
FUNCTION
DISPLAY:
OPTION SETTING
(step 2) Select "DIAL MODE".
KEY:
Push # until " DIAL MODE " is
indicated because the number of
# s changes by the model.
DISPLAY:
DIAL MODE
(step 3) Select, using "1" or "2".
KEY:
1
DISPLAY:
TONE SELECTED
KEY:
2
DISPLAY:
PULSE SELECTED
(step 4) End, using the "STOP" key.
KEY:
STOP
2 – 1
UX-510ATH
FO-1470TH
4
PRESS
OR #
Cursor
When initially registering,
the mode shows 1=TONE.
When registering again, the
mode which was registered
formerly is shown.
1=TONE, 2=PULSE