4 Deployment Procedure

4.4 Example of How to Conduct the Site Survey

1.
Set the S-PS to CS Area Check mode and walk around the site survey Master CS to confirm the CS
coverage area. The recommended area is where the RSSI is more than 8 and the Error Rate is less than
02%. Then, locate the Slave CS within that area.
CS Area Check using PS
: Planned Location
LED:
Slow amber flashing
Power
Source
Site Survey
Slave Mode
2.
Confirm whether the LED of the Slave CS is now flashing green slowly. If not, move the Slave CS to a
location where the LED is flashing green slowly.
After confirming the CS area using an S-PS, you need to confirm the radio signal
between the Master CS and Slave CS.
3.
Place the Master CS where the Slave CS was, and repeat steps 1 and 2 for all other locations.
40
Installation Guide
Power
Source
CS
coverage area
c
Site Survey
Master Mode
Power
Source
LED:
Slow green flashing
Power
Source
LED:
Red and green alternate flashing
Plotting a map with the RSSI
and Error Rate values makes
perfoming the site survey
easier. (You can check the map
when changing the location of
the CS.)
LED:
Red and green alternate flashing
Power
Source
CS coverage area