Name Programming; Entering Long Name Aborts Name Programming; Flash Key Operation; Programming - NEC DS2000 Release Notes

Hide thumbs Also See for DS2000:
Table of Contents

Advertisement

Name Programming

Entering Long Name Aborts Name Programming

Flash Key Operation

Programming

Program 0301 Data Entry Errors

Program 0501 Data Entry Errors

Program 1704 Data Entry Errors

Program 1802 Data Entry Errors

Program 8003 Data Entry Errors

DS2000 Release Notes
software versions 03.10.08 and above, these soft keys would appear but were not functional unless
these Class of Service options were enabled (Y).
Software version corrects a problem in version 03.10.08 and above where the system could exit pro-
gramming while the installer was entering a long name. In version 03.20.07, the system will wait
approximately 30 seconds after the last character is entered before aborting the programming mode.
When programming names, press FLASH to delete the character to the right of the cursor. In prior soft-
ware versions 03.10.08 and above, FLASH key operation when editing a name was not consistent.
Software version 03.20.07 corrects the following program entry problem that occurred when pro-
gramming 0301-Modem Installed in prior 03.**.** versions:
1.
Enter programming mode and select program 0301.
2.
Press HOLD or Vol Up repeatedly until you see MODEM INSTALLED .
3.
You cannot change the setting for 0301-Modem Installed until you press Vol Up to bypass
the option, then Vol Down to return to it.
Software version 03.20.07 corrects the following program entry problem that occurred when pro-
gramming 0501-Single Digit Access in prior 03.**.** versions:
1.
Enter programming mode and select program 0501.
2.
For digit 2, set FUNCTION Type to 3 (Line Group) + Vol Up.
3.
Change the setting of SINGL DGT ACCESS for the digit 2 (9=Yes, 6=No) + HOLD .
4.
Press CONF to exit.
5.
Repeat steps 1-3 to check your entry. The programmed value has not changed.
To save your entry in prior software versions, press Vol Up in step 3 instead of HOLD .
Software version 03.20.07 corrects a data entry problem in prior 03.**.** versions in which using
Vol Up
and Vol Down to quickly scroll through 1704-DSS Console Key Assignments will cause
programming to freeze. Pressing CONF will release the freeze.
Software version 03.20.07 corrects a data entry problem in 1802-Outgoing ANI ID for E1 trunks
that occurred in prior 03.**.** versions. After editing the entry, the blinking cursor would remain
after exiting the edit mode. This is an option for E1 MFC dialing that is not used in North America.
Software version 03.20.07 corrects an out-of-range data entry error in prior 03.**.** versions when
programming 8003-Trunk Number. For example, in DS2000 the first trunk number could display
as 240 instead of 1. This is now corrected.
DS2000 03.20.07 Release Notes
Software Corrections in 03.20.07
29 ◆ 03.20.07