Brother DCP-8110DN Service Manual page 196

Laser mfc
Hide thumbs Also See for DCP-8110DN:
Table of Contents

Advertisement

5) Fold one end of the second side CIS flat cable (end to be connected to the second side CIS
unit) at 205 mm for legal models and 201 mm for A4 models.
Mountain fold
6) As shown in the illustration below, pass the second side CIS flat cable through the FFC
holder ASSY while fitting the mountain-folded section to the rib on the FFC holder ASSY.
Then secure the second side CIS flat cable to the double-sided tape attached to the FFC
holder ASSY.
FFC holder ASSY
7) Fold the other end of the second side CIS flat cable (end to be connected to the main PCB
ASSY).
Legal models
Mountain fold
Valley fold
65mm
Reinforcing
plate
Fold at edge of reinforcing plate
Reinforcing tape
Legal models: 205mm
A4 models
Fig. 3-58
Pass through here.
Second side CIS flat cable
Fig. 3-59
Second
side CIS
95mm
flat cable
45°
Fig. 3-60
Second side CIS flat cable
: 201mm
Rib (fit mountain-folded section to rib)
A4 models
80mm
55mm
Fold at edge of reinforcing plate
3-50
Reinforcing plate
FFC holder ASSY
Double-sided tape
Second side CIS flat cable
45°
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents