Thin Lan Cable Requirements; Aui Cable - HP 10:10 LAN Bridge MB Installation And Reference Manual

Table of Contents

Advertisement

Thin LAN Cable Requirements

The thin coaxial cables used with the HP 10:10 LAN Bridge MB's ThinLAN port must comply
with the IEEE 802.3 Type 10Base2 requirements. Some RG-58 A/U or RG-58 C/U cable meet
these requirements.
The maximum length of a single thin coaxial cable segment is 185 meters.

AUI Cable

Minimum Pin-Out
Transceiver end
15-pin female
2
3
4
5
6
9
10
12
13
For this connection , you can use:
HP 92264D (1-meter thin AUI
extension, pin 4 not connected)
HP 92254A through H (6-meter through
48-meter thick AUI cables)
HP 92254J (5-meter thin AUI cable,
pin 4 not connected)
Some longer cables may have all 15 pins wired.
See the IEEE 802.3 standards document for
definitions of the pins not shown here.
A-4 Cables and Connectors
Bridge end
15-pin male
2
Control In circuit A
3
Data Out circuit A
4
Data In circuit Shield (common drain)
5
Data In circuit A
6
Voltage Common
9
Control In circuit B
10
Data Out circuit B
12
Data In circuit B
13
Voltage Plus
Signal
Male
Connector
Female
Connector