Power Synchronized Unit Connection; Power Cord Connection - Fujitsu ETERNUS DX200F Configuration Manual

All flash array
Hide thumbs Also See for ETERNUS DX200F:
Table of Contents

Advertisement

Chapter 4
Connecting Cables
4.2

Power Synchronized Unit Connection

2
Connect the host interface cable to the connection destination.
Connect the other end of the cable to the connection destination.
4.2
Power Synchronized Unit Connection
When using a power synchronized unit for power control, connect the power synchronized unit to the ETER-
NUS DX.
Refer to "Configuration Guide (Power Synchronized Unit)" for details about power synchronized units, the pro-
cedure for connecting power synchronized units to the ETERNUS DX, and required settings.
4.3

Power Cord Connection

Connect the power cords to the ETERNUS DX.
The ETERNUS DX has two (PSU#0 and PSU#1) power supply units.
Make sure that power cords are connected to all power supply units.
To help with power cord management and prevent incorrect connections, attach labels to the power
cords and make a note of connection origins and destinations.
The following procedure explains how to connect the power cords.
1
Connect the power cord to the ETERNUS DX.
(1)
Connect the power cord plugs to the power inlets of the power supply units.
Do
When connecting the host interface cables, position them so that they will
not obstruct replacement of the power supply unit or controllers by the main-
tenance engineer.
FUJITSU Storage ETERNUS DX200F All Flash Array Configuration Guide (Basic)
Copyright 2014 FUJITSU LIMITED
32
P3AM-8462-01ENZ0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents