3.
Remove the screws (x3) that secure the Decompression Pump Unit, and
remove the Decompression Pump Unit from the Base Frame.
Decompression Pump Motor cable
Decompression Pump Unit
Dowels (x6)
Hook
Figure 4-72. Removing the Decompression Pump Unit
DISASSEMBLY/ASSEMBLY
Base Frame
C.B.P. 3x8 (6±1Kgfcm)
C.B.P. 3x14 (6±1Kgfcm)
P.W. 3.3x0.5x10
Disassembly Procedures
When routing the Decompression Pump Motor cable, make
sure to secure it with the dowels (x6) and the hook on top of the
Decompression Pump Unit as shown in
When routing the decompression tube, confirm no clipped part
or fold on the tube. (See
Fig.
4-71,
Fig.
Figure 4-73. Installing the Decompression Pump Unit
Put the decompression tube through the groove on the Base
Frame (section A, B), and route it behind the FFC. (See
4-71.)
Make sure to insert the decompression tube into the socket on
the Cartridge Box Unit to the full to its base. (See
Revision C
Fig.
4-72.
4-73.)
Decompression Pump Unit
Decompression tube
Fig.
Fig.
4-71.)
131