3.
Remove the screws (x9) that secure the Upper Housing. (See
4.
Release the ribs (x4) and hooks (x2) of the Upper Housing.
3
4
Upper Housing
Left Housing
7
Panel Unit
C.B.A. 3x8 (black) (6±1Kgfcm)
C.B.P. 3x10 (black) (6±1Kgfcm)
Figure 4-17. Removing the Upper Housing (2)
5.
Lift the Upper Housing slightly and disconnect the Panel FFC from the Main
Board, and remove the Upper Housing together with the Panel Unit.
Upper Housing
Figure 4-18. Removing the Upper Housing (3)
DISASSEMBLY/ASSEMBLY
Fig.
4-17.)
5
1
6
2
Right Housing
8
9
Rib
Hook
C.B.P. 3x10 (6±1Kgfcm)
C.B.S. 3x8 (black) (8±1Kgfcm)
C.B.S. 3x6 (8±1Kgfcm)
Main Board
Panel FFC
Disassembly Procedures
6.
Remove the Panel Unit from the Upper Housing. (See
(p115).)
Insert the ribs (x4) of the Upper Housing to the inside of the
Housing L/R when installing the Upper Housing. (See
4-17.)
Tighten the screws in the order shown in
When installing the Front Harness Cover, insert the ribs (x3) of
the Front Harness Cover to the Upper Housing, and secure
them with the hooks (x2). (See
After removing/replacing the Upper Housing, make the specified
A D J U S T M E N T
R E Q U I R E D
adjustments. (See
Chapter 5
Revision C
4.2.3.1 "Panel Unit"
Fig.
Fig.
4-17.
Fig.
4-16.)
"ADJUSTMENT".)
108