Epson Artisan 700 Service Manual page 134

Hide thumbs Also See for Epson Artisan 700:
Table of Contents

Advertisement

Epson Artisan 700/Epson Stylus Photo PX700W/TX700W
3.
Loosen the screw (x1) that secures the Parallelism Bushing. (See
4.
Lift the PG Lever R and disengage the dowel of the Main Frame from the
shaft hole of the Parallelism Bushing. (See
5.
Rotate the Parallelism Bushing till the screw that secures the CR Motor Assy
can be seen.
Right side
PG Lever R
Dowel &
Parallelism Bushing
shaft hole
C.B.S. 3x6 (Secure it after PG Adjustment)
Figure 4-125. Removing the CR Motor (2)
6.
Remove the screws (x4) that secure the CR Motor, and remove the CR Motor
Assy.
Right side
Figure 4-126. Removing the CR Motor (2)
DISASSEMBLY/ASSEMBLY
Fig.
4-125.)
Fig.
4-125.)
Right side
PG Lever R
The screw that
secures the CR Motor
Parallelism Bushing
CR Motor Assy
Positioning hole & dowel
C.B.S. 3x6 (8±1Kgfcm)
C.B.S. 3x4 (8±1Kgfcm)
Disassembly Procedures
Be careful not to damage the Pinion Gear of the CR Motor with the
C A U T I O N
CR Motor Holder.
7.
Remove the screws (x2) that secure the CR Motor, and remove the CR Motor
from the CR Motor Holder.
CR Motor Holder
Figure 4-127. Removing the CR Motor (3)
Revision C
CR Motor
Groove
C.P. 3x4 (4±1Kgfcm)