Installing the hydraulic module
2.5
Installation precautions
2.5.1
•
The room in which the appliance operates must
comply with the prevailing regulations.
•
To facilitate maintenance and to allow access to the
various components, we recommend that you
provide sufficient space all around the hydraulic
module (figure 15).
•
Be careful not to bring inflammable gas near to the
heat pump during its installation, in particular when
it requires brazing
Figure 15 - Minimum installation clearances
around the hydraulic module and distances to the
combustible partitions
5
4
5
Installation and operating manual "1350-EN"
150 mm
200 mm
150 mm
1000 mm
Figure 17 - Removing the sides and fixing the support (S)
The appliances are not fireproof and should not
therefore be installed in a potentially explosive
atmosphere.
Positioning the hydraulic module
2.5.2
- 1, 2, 3 : Remove the front panel (2 screws A, figure 16)
- 4, 5 : Remove the sides (4 screws B, figure 17).
- Fix the support solidly (3 screws and plugs) to a flat,
hard-wearing wall (not a light partition) ensuring
that it is correctly levelled.
- Hook the appliance onto its support.
- Refit the sides.
- Refit the front facing.