Fujitsu AOYA18LALL Installation And Operating Manual page 36

Heat pump air/water split single service
Hide thumbs Also See for AOYA18LALL:
Table of Contents

Advertisement

Heat pump, Split, single service
Line
Function
576
U
Standard values
Time programme 5 / Cooling
If the installation is fitted with the cooling kit (Only with the cooling kit option)
600
U
Pre-selection (day / week)
Mon-Sun Mon-Fri Sat-Sun Monday Tuesday...
601
U
1st phase On (start)
602
U
1st phase Off (end)
603
U
2nd phase On (start)
604
U
2nd phase Off (end)
605
U
3rd phase On (start)
606
U
3rd phase Off (end)
616
U
Standard values
Yes + OK: The standard values memorised in the regulator replace and cancel the customised heating
programmes. Your customised settings are therefore lost.
Holidays, heating circuit 1
641
U
Preselection
642
U
Date holidays start (Day / Month)
643
U
Date holidays end (Day / Month)
648
U
Heating schedule during the holidays
Holidays, heating circuit 2
If the installation consists of 2 heating circuits (Only with the 2nd circuit kit option)
651
U
Preselection
652
U
Date holidays start (Day / Month)
653
U
Date holidays end (Day / Month)
658
U
Heating schedule during the holidays
Heating adjustment, circuit 1
710
U
Comfort ambient temperature setpoint
712
U
Reduced ambient temperature setpoint
714
U
Frost-free ambient temperature setpoint
716
S
Maximum comfort setpoint
720
I
Heating curve slope (See Figure 41)
721
I
Off-set of the heating curve (See Figure 42)
726
S
Auto-adaptation of the heating curve (see § 3.3.2)
730
I
Summer/Winter heating limits
When the average of the outside temperatures over the past 24 hours reaches 18°C, the regulator switches off the
heating (as an economy measure).
During summer mode, the display shows "Eco".
36
Setting range
or display
no, yes
00 : 00... - -:- -
00 : 00... - -:- -
00 : 00... - -:- -
00 : 00... - -:- -
00 : 00... - -:- -
00 : 00... - -:- -
no, yes
Period 1 to 8
01.01... 31.12
01.01... 31.12
Frost protection,
Reduced
Period 1 to 8
01.01... 31.12
01.01... 31.12
Frost protection,
Reduced
From reduced temperature
to 35°C
from frost-free temp... to
comfort temperature
from 4°C...
to reduced temperature
20 °C... 35 °C
0.1... 4
-4.50 °C... 4.5 °C
off, on
8 °C ... 30 °C
This function is only active in automatic mode.
Installation and operating manual "1350-EN"
Setting
Basic
setting
increment
no
Mon-Sun
10 min
6 : 00
10 min
22 : 00
10 min
- -:- -
10 min
- -:- -
10 min
- -:- -
10 min
- -:- -
no
Period 1
1
1
Frost
protection
Period 1
1
1
Frost
protection
0,5 °C
20 °C
0,5 °C
18 °C
0,5 °C
8 °C
1 °C
28 °C
0,02
0.5
0,5 °C
0 °C
on
0,5 °C
18 °C