The error status from the controller to the host is as shown in
the table below.
b7 Not used. ("0" is always displayed.)
b6 Power interruption notice
b5 Not used. ("0" is always displayed.)
b4 CH2 reception data exits.
b3 CH1 reception data exits.
b2 Power interruption process complete
b1 Not used. ("0" is always displayed.)
b0 Not used. ("0" is always displayed.)
Display
SRN Self Check
DATA RETRY CNT.=xxx
ACK RETRY CNT.=xxx
DIAG 0
:xxxxxxxx
DIAG 1
:xxxxxxxx
DIAG 5 H
C
:xxxxxxxx
DIAG 5 H
C :xxxxxxxx
!
Terminating procedure
Perform the service reset.

2) SRN Flag Send Check


Check content
Execute diagnostics 3 command to send Flag (7EH) continuously.
Display
SRN Flag Send Check
!
Terminating procedure
Perform the service reset.

3) SRN Data Send Check


Check content
Execute diagnostics 4 command to send data of 00H ∼ FFH
(256Byte) as one packet at 12.8msec packet interval at 1Mbps
continuously.
Display
SRN Data Send Check
!
Terminating procedure
Perform the service reset.
The number of resending is
displayed in xxx with a decimal
number.
In the sequence of b7, b6, ..., b0
from the left. "1" is displayed in
case of an error, and "0" when
normal.
In the sequence of b7, b6, ..., b0
from the left. "1" is displayed in
case of an error, and "0" when
normal.
In the sequence of b7, b6, ..., b0
from the left. "1" is displayed in
case of an error, and "0" when
normal.
In the sequence of b7, b6, ..., b0
from the left. "1" is displayed in
case of an error, and "0" when
normal.

4) Data Transmission Check

Data transmission is checked in an actually composed system. The
system is composed of one master machine and max. 15 satellite
machines.
Note for starting the check
When checking the set in which the SRN setting has been made,
cancel the SRN setting before starting this check.
When checking the actually composed system, disconnect the
SRN cables of the sets which are not checked, or cancel the SRN
setting. If it is set to "SRN exits," data may be destroyed.
The transmission check setting must be performed after canceling
the SRN setting of all the sets in the system. First, set the satellite
machines, then set the master machine.

Setting procedure
Satellite machine setting
In the menu screen, select "Data Transmission Check (Satel-
lite)."
The display is as follows:
Data Transmission Check (Satellite)
Input Terminal Number :
Enter the terminal No. (000 ∼ 015) of the machine to be
checked and press the Touch panel. The display is as shown
below.
Data Transmission Check (Satellite)
Input Terminal Number : xxx
Data Sequence Number : 0000
Master machine setting
In the menu screen, select "Data Transmission Check (Master
Machine)." The display is as shown below.
Data Transmission Check (Master)
Input Master Terminal Number :
Enter the terminal No. (000 ∼ 015) of the machine to be
checked and press the Touch panel. The display is as shown
below.
Data Transmission Check (Master)
Input Master Terminal Number
Input Satellite Terminal Number:
Enter the terminal No. (000 ∼ 015) of the machine to be con-
nected to the machine to be checked and press the ENTER
key. The display is as shown below.
Data Transmission Check (Master)
Input Master Terminal Number
Input Satellite Terminal Number:xxx
6 – 8
The entered
terminal No. is
displayed.
:xxx
The entered
terminal No.
is displayed.
:xxx
The entered
terminal No.
of satellite
machine is
displayed.