10. Power-up the base unit

1. Confirm that both power receptacles on the rear of the base unit are
connected to working outlets. The green LEDs above each receptacle
should be ON and the green front panel READY LED should blink.
NOTE: The outlets should not be controlled by a wall switch, which can
inadvertently remove power form the storage units.
2. Press the Power switch on the lower right side of the front panel of the
base unit to the ON position:
The base unit performs its Power On Self Test and the activity LEDs on
the drives flash and then go ON. After a few minutes, the front panel
READY LED goes ON.
Legend:
NOTE: When the bezel is removed, the Power switch is identified on the
enclosure as MAIN SW.
Figure 1-14: Front View of Base Unit
Ready LED (green)
Power LED (green)
POWER switch (ON position)
POWER switch (OFF position)
Alarm LED (red). If this LED goes ON, refer to the User's Guide.
Warning LED (orange). If this LED goes ON, refer to the User's Guide.
Hitachi AMS 2100/2300 Getting Started Guide