No. Part to be replaced
Sensor
13
TCJ, TF(TCJ2) and
TA(TWI)
Sensor TC1 and
14
TC2(TWO)
Work procedure
1. Detachment
1) Carry out the detachment of item
2) Remove connectors which are connected from the
control P.C.board to the other parts and then remove
wiring from the clamp.
CN102 .... TCJ
Red
CN103 .... TF(TCJ2) Green 2P
CN104 .... TA(TWI)
Yellow 2P
2. Attachment
1) Carry out installation by following the detachment
procedure in reverse.
NOTE:
• Be careful in the insertion direction about attaching the
sensor, as shown below.
• Let TCJ, TA (TWI) and TF (TCJ2) wiring pass through
the letf side clamps.
Refer to item
(Electrical control box).
4
1. Detachment
1) Carry out the detachment of item
box).
2) Remove connectors which are connected from the
control P.C.board to the other parts and then remove
wiring from the clamp.
CN101 ... TC2(TWO) Black
CN100 ... TC1
Brown 3P
2. Attachment
1) Carry out installation by following the detachment
procedure in reverse.
NOTE:
• Be careful in the insertion direction about attaching the
sensor, as shown below.
• Let TC1 and TC2(TWO) wiring pass through the right
side clamps.
Refer to item
(Electrical control box).
4
For TC2(TWO) and TC1
For TC2(TWO) and TC1
Insertion drection :
Insertion drection :
(Front panel).
1
2P
(Electrical control
4
2P
TC1
Tube color:Blue
TC2(TWO)
Tube color:Black
– 74 –
Remarks
TCJ
TCJ
Tube color:Red
Tube color:Red
TA(TWI)
TA(TWI)
Tube color:Black
Tube color:Black
For TWI, TCJ and TCJ2
For TWI, TCJ and TCJ2
Insertion drection :
Insertion drection :
TF(TCJ2)
TF(TCJ2)
Tube color:Gray
Tube color:Gray