Generator Test; Check) - Suzuki 2006 SX4 Service Manual

Hide thumbs Also See for 2006 SX4:
Table of Contents

Advertisement

1J-5 Charging System:
Generator Test (Undercharged Battery Check)
This condition, as evidenced by slow cranking or
indicator clear with dark or light yellow dot can be
caused by one or more of the following conditions even
though indicator light may be operating normal.
The following procedure also applies to cars with
voltmeter and ammeter.
1) Make sure that undercharged condition has not been
caused by accessories left on for extended period of
time.
2) Check drive belt for proper tension.
3) If battery defect is suspected, refer to "Battery
Description".
4) Inspect wiring for defects. Check all connections for
tightness and cleanliness, battery cable connections
at battery, starting motor, ignition ground cable and
no "C" terminal circuit at ground.
5) Connect switch (6), load (5), battery (4), voltmeter
(3) and ammeter (2) to generator (1) as shown in
figure.
Voltmeter: Set between generator "B" terminal
and ground.
Ammeter: Set between generator "B" terminal
and battery (+) terminal.
NOTE
Use fully charged battery.
6) Measure current and voltage.
No-Load Check
1) Run engine from idling up to 2000 rpm and read
meters.
NOTE
Turn off switches of all accessories (wiper,
heater etc.).
Specification for undercharged battery (No-load

check)

Current: 10 A
Voltage: 14.2 – 14.8 V (at 20 °C, 68 °F)
NOTE
S6RW0C1A04003
Consideration should be taken that voltage
will differ somewhat with regulator case
temperature as shown in figure.
2) Using service wire, ground "C" terminal (1) of
generator.
3) Measure voltage between "B" terminal of generator
and body ground.
Voltage: 12.5 – 13.1 V (at 20 °C, 68 °F)
• If voltage is higher than standard value
If voltage is higher than standard value, check ground
of brushes.
If brushes are not grounded, replace IC regulator.
If voltage is lower than standard value, proceed to the
IYSQ011A0007-01
following check.
Load Check
1) Run engine at 2000 rpm and turn on head light and
heater motor.
2) Measure current and if it is less than 30 A repair or
replace generator.
(V)
16.0
15.5
15.0
14.5
[A]
14.0
13.5
13.0
-30
0
20
22
68
[B]
[A]: Regulated voltage (V)
[B]: Heat sink temperature (°C)
120 (˚C)
248 (˚F)
I6RS0B1A1002-01
I5JB0A1A0011-01