Electrical System Quick Checks; Electrical System Quick Checks; Battery Test (Open Circuit) - Toro Greensmaster 3150 Service Manual

Engine-powered riding greens mower
Hide thumbs Also See for Greensmaster 3150:
Table of Contents

Advertisement

Electrical System Quick Checks

Battery Test
Use a multimeter to measure the voltage between the
battery terminals.
Set the multimeter to the DC volts setting. The battery
should be at a temperature of 60
o
37.8
C). The ignition key should be off and all accesso-
ries turned off. Connect the positive (+) meter lead to the
positive battery post and the negative (–) meter lead the
the negative battery post.
Note: This test provides a relative condition of the bat-
tery. Load testing of the battery will provide additional
and more accurate information.
Electrical System
o
o
o
to 100
F (15.5
to
Page 5 – 8
Voltage Measured
12.68 V (or higher)
12.45 V
12.24 V
12.06 V
11.89 V
Battery Charge Level
Fully charged (100%)
75% charged
50% charged
25% charged
0% charged
Greensmaster 3150

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents