9.12 Handset holder (Upper cover L for no Handset model) / Upper cover R

(1) Open the control panel ASSY.
(2) Disconnect the hook switch PCB harness and the control panel cover sensor harness
from the main PCB ASSY, and release them from the guide.
(3) Release the wiring of the control panel cover sensor harness from the guides of the
handset holder.
(4) Remove the taptite bind B M4x12 screw from the handset holder. And release the hook,
and slide the handset holder in the direction of the arrow to remove it from the machine.
(5) Remove the taptite bind B M4x12 screw from the upper cover R. And release the hook,
and slide the upper cover R in the direction of the arrow to remove it from the machine.
Handset holder
Hook switch PCB harness
Guide
Control panel cover
sensor harness
Control panel cover
sensor harness
Hook switch
PCB harness
Harness routing : Refer to
Taptite bind B M4x12
Hook
Guides
Main PCB ASSY
"17. Hook switch PCB ASSY/Control panel cover
Hook
Control panel ASSY
Fig. 3-21
3-37
Upper cover R
sensor".