(5) Release the panel PCB harness from the securing fixtures.
(6) Open the control panel ASSY at an angle of 45 degrees, and remove it from the
document chute ASSY in the direction of the arrow.
Control panel ASSY
An angle
of 45°
Harness routing : Refer to
Panel PCB
harness
Fig. 3-24
"15. Panel unit/ADF
3-40
motor".
Document chute ASSY
Confidential