Error code 1A to 1D
These errors do not usually occur in the normal use. The conceivable causes are noise
around the installation site, fluctuation of the power supply voltage, and failures in the
software.
---
An unidentified error occurred.
<User Check>
• Turn OFF the power switch, and turn it ON again after a while.
Step
1
Main PCB failure
Error code 1E
Drum End Soon
The drum unit will reach the end of life soon.
<User Check>
• Prepare a new drum unit.
Step
1
Main PCB failure
Error code 1F to 23
These errors do not usually occur in the normal use. The conceivable causes are noise
around the installation site, fluctuation of the power supply voltage, and failures in the
software.
---
An unidentified error occurred.
<User Check>
• Turn OFF the power switch, and turn it ON again after a while.
Step
1
Main PCB failure
Cause
Replace the main PCB ASSY.
Cause
Replace the main PCB ASSY.
Cause
Replace the main PCB ASSY.
2-25
Remedy
Remedy
Remedy
Confidential