- Register the voice control data when connecting to MG-SIP16. If the settings are not

6.16 AMGVL

specified by this command, the values will be set to "G711" and "40ms" automatically.
A RT: Specify Physical Route Number (MG-SIP16).
LOC-ID: Specify Destination Location ID (Destination MG-SIP16). *LOC-ID=0 must be set when
IPPAD card is mounted.
B RT: Specify Physical Route Number (MG-SIP16) in the case of tandem connection between MGs.
SETTING OF SERVICE TYPE (VOICE PACKET): Specify QoS settings of Voice Speech
PAYLOAD TYPE: Specify Payload type. *G.711 and 20ms must be set for public SIP network.
PAYLOAD SIZE: Specify Payload size.
Unless the AMGVL Command is not used for the registration, the AIVCL command is
Note:
required to register the attributes. For more information, refer to the Office Data Specifications.
- Assign the Calling Number Pattern (CNP) on an Access Code basis. *When this

6.17 ACNAL

command is used, assign ARTD command CDN66 to DC=15.
• Settings for a Call Originated to SIP Network
Specify Calling Number Pattern against route for Caller ID Notification and Access Code.
IC/OG = OG (Outgoing)
RT: Enter Route Number to be sent Caller ID Notification per Access Code.
ACC: Enter Access Code.
CNP: Enter Calling Number Pattern.
To modify CNP set by the ACNAL command, use the ACND command; ACNDN
Note:
command cannot be used.
• Settings for a Call Arrived from SIP Network
Specify Calling Number Pattern against route for Caller ID Notification and Access Code.
IC/OG = IC (Incoming)
RT: Enter Route Number to be arrived.
ACC: Enter Access Code.
DC: Dialed Number Confirmation
- Assign the data for number change to CNP has been specified by the ACNAL command

6.18 ACND

CNP: Calling Number Pattern
SKIP: Skip Digit
ADD: Number of Digits of the Additional Number
DC: Digit Code of the Additional Number
- Change Digit Code according to DID Addressing.

6.19 ACDD

DAY/NIGHT: Day/Night Mode
RT: Enter the B-Channel Route Number.
DC: Enter Number of digits for this DC must match the data in DC of the ARTD command.
CDC: Enter Change Digit Code [Maximum 24 digits]
AD: Enter Additional Dialing
XFR: Enable/Disable Transfer Service
After the registration has been completed, reset MG-SIP16 (ON OFF ON).