7.3 Operation Check
After the configuration setting is completed, check the MG-SIP16 works normally.
STEP 1: Reboot MG-SIP.
Open reboot command to save the settings.
STEP 2: After the MG-SIP16 is rebooted, the following is displayed on Maintenance Console.
If a message indicating MG-SIP OFFLINE START is displayed, make sure of the
Note:
following:
- Confirm a cable connected to SIP network is inserted firmly.
- Check the Link lamp lights.
If any message does not appear on the screen for three minutes, it could be a communication
problem between MG-SIP16 and MGC (DRS). Confirm the LAN cable and the IP Address on
IPX side.
STEP 3: Make sure of the connectivity between IPX network and SIP network.
Open show status command to confirm the network registration status on IPX and SIP sides.
STEP 4: Make sure of the registration status of MG-SIP16.
Open DIMG command on Windows MAT to check the registration status.
7.4 Diagnosis
STEP: Diagnose the user program is working properly.
On the Maintenance Console, type "ping appropriate IP address" to make sure the MG-
SIP16 connects the network and operates normally.
7.5 Maintenance Console Commands
7.5.1 How to Use the Maintenance Commands
• Connection Settings
A communication between Maintenance Console and MG-SIP16 is established via communications
software such as HyperTerminal, which comes with Windows.
When the program is activated, messages are displayed. After a prompt "->" is displayed, enter "config"
after the prompt to login.
MG-SIP
Page 23 of 75