Starting Oem Programs; Enabling/Disabling Error Log During Boot Up - Siemens SINUMERIK 810D Commissioning Manual

Hide thumbs Also See for SINUMERIK 810D:
Table of Contents

Advertisement

Configuring the system
2.3 User-specific settings during boot up
2.3.3

Starting OEM programs

Overview
You can start OEM programs directly before starting the HMI system software. This requires
these programs (or their links) to be stored in subdirectories of the directory C:\RunOEM.
Starting sequence
The subdirectories are executed in the order listed. The programs within a subdirectory are
started in the chronological order in which they were placed in the subdirectory.
● Programs in the C:\RunOEM\SeqOnce subdirectory are started once and sequentially,
● Programs in the C:\RunOEM\Seq subdirectory are started sequentially whenever the
● Programs in the C:\RunOEM\ParOnce subdirectory are started once and simultaneously.
● Programs in the C:\RunOEM\Par subdirectory are started simultaneously whenever the
Not only program files, but also other types of file can be stored in the subdirectories, which
are then opened in accordance with their file type.
For example, ".txt" files are opened using Notepad, ".htm" files are opened using Internet
Explorer.
2.3.4

Enabling/disabling error log during boot up

Application
Each time the system is booted up, information is written to a block in the file D:\$$Base.log,
which contains the date, time and nature of administrative interventions.
Information about the booting controlled by the HMI Manager, can be displayed on the
screen and written to log file D:\$$Base.log.
Output in log file
The output is controlled by registry values:
● Type of information
2-16
i.e., a program is not started until the previously started program is completed.
system is ramped up, i.e., a program is not started until the previously started program is
completed.
They run parallel with the HMI system software.
system is ramped up. They run parallel with the HMI system software.
The type of information to be output is set via registry value
"HKLM\SOFTWARE\Siemens\SINUMERIK\Basic software\<version>\HMI
Manager\InfoLevel":
Commissioning Manual, 10/2006, 6FC5397-0DP10-0BA0
PCU Basesoftware (IM6)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840diSinumerik 840d